Вы просматриваете старую версию сайта. Предлагаем Вам посетить наш новый сайт 6435206.ru
Panazip
Сервис и запасные части
(495) 643-5206
ok@panazip.ru

Лазерные многофункциональные устройства Panasonic

Коды ошибок в МФУ Panasonic DP1820/8020/2310/2330/3010/3030/3510/3530/4510/4530/6010/8035/8045/8060

В МФУ Panasonic формата А3 все коды ошибок унифицированны и совпадают (за исключением аппаратов где некоторуе узлы отсутствуют или принципиально другие).

Mechanical Error Codes (E Code)

E1: Optical Unit Error

Code Function Possible Cause(s)

E1- 01 Abnormal Platen Glass Scanning

1. Home Position Sensor connector disconnected.

2. Home Position Sensor defective.

3. Scanner Motor connector disconnected.

4. Scanner Motor defective.

5. Scanning Mechanism defective.

6. SDR PCB connector disconnected.

7. SDR PCB defective.

8. SPC PCB connector disconnected.

9. SPC PCB defective.

10. LVPS defective.

E1- 20 Laser Unit Horizontal

Synchronization

1. LSU connector disconnected.

2. LSU defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

E1- 22 Polygon Motor Synchronization

1. Polygon Motor connector disconnected.

2. SPC PCB connector disconnected.

3. LSU connector disconnected.

4. Polygon Motor defective.

5. LVPS defective.

6. SPC PCB defective.

E1- 31 Scanning Lamp (does not turn On)

1. INV PCB connector disconnected.

2. INV PCB defective.

3. Scanning Lamp defective.

4. LFB PCB connector disconnected.

5. SDR PCB connector disconnected.

6. SDR PCB defective.

7. SPC PCB connector disconnected.

8. LVPS defective.

E1- 34 Scanning Lamp Harness

1. INV PCB connector disconnected.

2. LFB PCB connector disconnected.

3. Scanning Lamp connector disconnected.
E1- 40 Book Fan Motor Rotation 1. Book Fan connector disconnected.

2. Book Fan defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

5. LVPS defective.

E1- 45 LSU Fan Motor Rotation 1. LSU Fan connector disconnected.

2. LSU Fan defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

5. LVPS defective.
E2: Lift DC Motor Error

Code Function Possible Cause(s)

E2- 01 Lift Motor Rotation

(1st Paper Tray)

1. Level Sensor connector disconnected.

2. Level Sensor defective.

3. Lift Mechanism defective.

4. Lift Motor connector disconnected.

5. Lift Motor defective.

6. SPC PCB connector disconnected.

7. SPC PCB defective.

8. LVPS defective.

E2- 02 Lift Motor Rotation (2nd Paper Tray)

1. Level Sensor connector disconnected.

2. Level Sensor defective.

3. Lift Mechanism defective.

4. Lift Motor connector disconnected.

5. Lift Motor defective.

6. SPC PCB connector disconnected.

7. SPC PCB defective.

8. CST2 PCB connector disconnected.

9. CST2 PCB defective.

10. LVPS defective.

E3: Development System Error Code Function Possible Cause(s)

E3- 01 Toner Bottle Motor Rotation 1. Toner Bottle Motor connector disconnected.

2. Toner Bottle Motor defective.

3. Toner Bottle Motor Drive Mechanism defective.

4. Toner Bottle installed incorrectly.

5. SPC PCB connector disconnected.

6. SPC PCB defective.

7. Toner Bottle Home Position Sensor connector disconnected.

8. Toner Bottle Home Position Sensor defective.

E3- 03 Toner Density Sensor Gain

1. Sensor connector disconnected.

2. Sensor defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

E3- 20 Main Motor Rotation 1. Drive Mechanism defective.

2. Main Motor connector disconnected.

3. Main Motor defective.

4. SPC PCB connector disconnected.

5. SPC PCB defective.

6. LVPS defective.

E3- 40 Copy Density Sensor Output Adjustment

1. CDS PCB connector disconnected.

2. CDS PCB defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.
E4: Fuser Unit Error Code Function Possible Cause(s)

E4- 01 Fuser Warm-up Temperature 1. Fuser Thermistor dirty.

2. Thermistor position incorrect.

3. Thermistor defective.

4. Thermistor connector disconnected.

5. Fuser Lamp connector disconnected.

6. Fuser Lamp defective.

7. Fuser Thermostat defective.

8. Thermal Fuse defective.

9. ACD PCB connector disconnected.

10. ACD PCB defective.

11. NFL PCB connector disconnected.

12. NFL PCB defective.

13. SPC PCB connector disconnected.

14. SPC PCB defective.

15. Fuser temperature low. (Adjust F6-31)

E4- 02 Fuser Paper Jam

1. Paper Jam in Fuser Unit.

2. Paper Exit Sensor 1 or 2 disconnected.

3. Paper Exit Sensor 1 or 2 defective.

4. SPC PCB connector disconnected.

5. SPC PCB defective.

E4- 10 Fuser Fan Motor Rotation 1. Fuser Fan connector disconnected.

2. Fuser Fan defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

5. LVPS defective.
E5: System Error

Code Function Possible Cause(s)

E5- 05 Vp (+24V, Scanner) 1. SDR PCB connector disconnected.

2. SDR PCB defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

5. LVPS defective.

E5- 11 Printer Engine Communication Abnormal

1. SPC PCB connector disconnected.

2. SPC PCB defective.

3. SC PCB connector disconnected.

4. SC PCB defective.

E5- 12 Scanner Engine

Communication Abnormal

E5- 17 Scanner Synchronization

E5- 19 Scanner Line Synchronization

E5- 42 Total Counter Connection 1. Total Counter connector disconnected.

2. Total Counter defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

E5- 60 Power Supply Cooling Fan Motor Rotation

1. Cooling Fan connector disconnected.

2. Cooling Fan defective.

3. SPC PCB connector disconnected.

4. SPC PCB defective.

5. LVPS defective.

Запасные части      Модели

Некоторые из наиболее популярных запасных частей для данной категории.
Если вы не знаете код нужной вам детали, выберите вашу модель из списка и просмотрите её описание. Возможно, нужная деталь обнаружится там. Если вы знаете код нужной детали, но в списке её нет, отправьте нам запрос.